Symbols and metadata
This section explains how to configure a symbol, how its name becomes a topic, and what metadata each message carries once it has been read.
Addressing symbols
Symbols are specified as name[:key=value...]. Each option names the field it sets.
MAIN.var
default
default
MAIN.var:cycleTime=100
default
100
MAIN.var:maxDelay=50
50
default
MAIN.var:maxDelay=50:cycleTime=100
50
100
Rules:
Options are
key=value; the only keys aremaxDelayandcycleTimeA bare number is ignored with a warning, and the default is kept
Values without a unit are milliseconds;
cycleTime=10msandcycleTime=10are the sameInvalid or omitted values fall back to the plugin-level
maxDelay/cycleTimedefaultsBoth options only apply when
readTypeisnotification; withintervalthe plugin polls everyintervalTimeand per-symbol timing is ignored
Examples:
MAIN.MYBOOL: uses plugin-level defaults for bothMAIN.MYTRIGGER:maxDelay=0:cycleTime=10: 0ms max delay, 10ms cycle timeMAIN.MYSENSOR:cycleTime=10: default max delay, 10ms cycle time.superDuperInt: global variable (TC2, must start with.)
TwinCAT 3 qualifies every symbol with the object that declares it. A global variable is <GVL name>.<variable>, where <GVL name> is whatever the Global Variable List object is called. TwinCAT names a new GVL GVL, so GVL.nCounter is the common case; a list named GVL_ProcessData gives GVL_ProcessData.nCounter. Program variables use the POU name: MAIN.MyVariable, PRG_Machine.nUpdates. There is no fixed GVL_ prefix and no leading dot.
TwinCAT 2 puts globals in one flat namespace with no list name, reached by a leading dot: .nCounter, .stProcessData.fValue. Program variables still carry the POU name and no dot: MAIN.someVar.
Symbol names are case-insensitive, so the PLC accepts any casing. The metadata always carries the casing you configured: TwinCAT 3 returns the original casing, and TwinCAT 2 returns uppercase, which the plugin maps back to what you wrote.
Symbol names in topics
ads_symbol_name becomes the last segment of the UMH topic, where a dot separates levels, so the symbol name has to be rewritten to fit. Array indices keep one separator, a TwinCAT 2 global's leading dot is dropped (it marks the namespace and is not part of the name), and runs of underscores collapse:
PLC symbol
ads_symbol_name
GVL_ProcessData.stMachineStatus.stMotor1.fSpeed
GVL_ProcessData_stMachineStatus_stMotor1_fSpeed
PRG_Diagnostics.astSensorHistory[0].fValue
PRG_Diagnostics_astSensorHistory_0_fValue
.afMeasurements[0] (TC2 global)
afMeasurements_0
.nMasterCycleCounter (TC2 global)
nMasterCycleCounter
_internalVar
_internalVar (a leading underscore may be the PLC's own naming)
The original is always available as ads_symbol_name_original, so a symbol can still be traced back to the PLC. Two symbols can in principle collapse to the same tag name (.a[0] and a variable actually named a_0), so if a program relies on that distinction, use ads_symbol_name_original in the tag_processor instead.
Structs and arrays
A named member reads like any other symbol:
Naming the struct itself returns the whole thing as one message, with the members as nested JSON:
That form needs loadSymbols: true, because the layout comes from the PLC's datatype table. Without it the read fails for the struct and the log says Batch read produced no value for symbol. Reading a member by name needs no table either way.
Metadata outputs
Each symbol produces one message whose payload is the value read from the PLC, so meta("ads_symbol_name") is how a following bloblang processor tells them apart.
ads_symbol_name
PLC symbol name as one topic segment; see Symbol names in topics
ads_symbol_name_original
The symbol exactly as the PLC names it, dots and brackets intact (e.g. PRG_Diagnostics.astSensorHistory[0].fValue)
ads_unified_address
The unifiedAddress entry this message came from, exactly as configured and including its options (e.g. GVL_ProcessData.nCounter:cycleTime=10ms). Always set. For an entry with no options this equals ads_symbol_name_original
ads_datatype
PLC data type string as reported by the symbol table (e.g. DINT, E_MachineState, REAL). Set after first successful symbol resolution, may be absent on the very first batch after connect.
ads_base_type
Resolved IEC 61131-3 primitive underlying the symbol (e.g. DINT for an INT-aliased enum). Absent when the type does not resolve to a primitive
ads_data_size
Byte length of the symbol as reported by the PLC (e.g. 4 for DINT, 82 for STRING).
ads_tag_type
Value shape of the payload: number, bool, or string. Set for every message so downstream processors can branch on payload type without inspecting ads_datatype/ads_base_type.
timestamp_ms
Unix milliseconds for when the value was captured. For readType: notification, this is the PLC's sample time for that update; for readType: interval, this is the time the plugin performed the read.